A pure water solution, integrating Elix® technology for your essential needs Find MSDS or SDS. This ensures you receive the user manual in local language and a power cord adapted to the. Operating Weight, 17.2 - 18.5 kg (46.8 - 49.5 lb). Our customer service and technical service. Elix ® Advantage Water Purification System. This ensures you receive the user manual in local language and a power. A qualified Millipore®. Representative should perform any work that needs to. Millipore, A10, Elix, Q-Gard, Milli-Q, Millipak and Milli-RO are registered.
Millipore Elix 10
. Description of Manager Menu.52 Ready Mode.56 Overview.56 Ready Mode - General information.57 Description of Ready Menu.58 Using the Milli-Q System.61 Overview.61 Dispensing water.62 Main Keypad, Display and LEDs.63 Q-POD Keypad and Display.65. Maintenance.66 Overview.66 Maintenance Schedule.67 Replacing the Progard Pack.68 Replacing the Quantum Cartridge.70 Replacing a POD Pak.73 Cleaning the A10 TOC Monitor.76 Sanitising or cleaning the RO Cartridge.78 Cleaning the Inlet Strainer.79 Replacing the Tank Vent Filter.80 Alarms and Alerts.81 Overview.81 Alert messages.82.
Some of the more important topics in this chapter are:. Safety Information. Where to find information Contents This chapter contains the following topics: Topic See Page About this User Manual About Millipore Legal Information Safety Information Where to find information. If this User Manual is not the correct one for your Water Purification System, then please contact Millipore.
Terminology The term “Milli-Q Integral Water Purification System” is replaced by the term “Milli-Q System” for the remainder of this User Manual unless otherwise noted. See the business card(s) on the inside cover of the User Manual binder. Internet The Millipore Internet site address can be used to submit a question to Millipore via electronic mail. The Millipore Internet site can be used to find addresses, telephone/fax numbers and other information.
Millipore Corporation assumes no responsibility for any errors that might appear in this document. This manual is believed to be complete and accurate at the time of publication. In no event shall Millipore Corporation be liable for incidental or consequential damages in connection with or arising from the use of this manual. Legal Information, Continued Trademarks Millipore, A10, Elix, Q-Gard, Milli-Q, Millipak and Milli-RO are registered trademarks of Millipore Corporation. BioPak, Quantum, Milli-RX, RiOs and Q-POD are trademarks of Millipore Corporation. All other trademarks are trademarks of their respective manufacturers.
© 2007 MILLIPORE CORPORATION. PRINTED IN FRANCE. ALL Copyright RIGHTS RESERVED. Safety Information Statement Your Milli-Q System should be operated according to the instructions in this manual. In particular, the hydraulic and electrical specifications should be followed and met. It is important to use this equipment as specified in this manual; using this equipment in a different manner may impair the safety precautions of the Milli-Q System.
Where to find information Organisation of This block will explain how this manual is organised. This User Manual Cross reference This block will contain a cross reference table. The table will be a quick way table for the reader to find information about items that might have different names than those used in this manual. Product Information Overview Purpose This chapter contains topics related to the Milli-Q System. Some of the more important topics in this chapter are:. Installation requirements. Consumable information.
Dimensions of various components of the Milli-Q System Contents This chapter contains the following topics. Cabinet Description Part Function Main Display LEDs Main Keypad Door for Quantum Cartridge Door for Progard Pack Connections for ports and cables Ports and cables. Port 8 Water to E-POD tubing to drain Dispenser (Accessory) Port 2 Feedwater to Port 9 Water to and Milli-Q System from Reservoir Port 3 Water to Q-POD Power Cord Dispenser (100 – 240 V) Port 4 Water from Q. Q-POD Dispenser Description Part Function Plunger POU Dispenser POD Pak (BioPak Ultrafilter pictured here) Mast Base Q-POD Dispenser Display Q-POD Dispenser Keypad Ports and cables Part Function Printer cable connection PS/2 cable connection + Termination Plug connection. Footswitch connection Tubing connections RC-Link The entire RC-Link is pictured here. The RC-Link is the set of tubings and the PS/2 cable inside a sheath.
Part Function Termination Plug PS/2 Cable Tubings Height adjustment Step Action Result Press the button on the Q-POD picture here Arm. Tank Millipore Millipore recommends using a Tank having the following catalogue number: recommends XXXXXXXXX (please list this in the Customised Data File). Example A picture of a Tank alongside a fully installed Milli-Q Integral System will be shown here. Consumables Diagram The water flow through a Milli-Q System is shown here in a flow diagram. The various consumables are described below.
For more information about the flow diagram, please refer to the Milli-Q System brochure. Please contact Millipore if you would like to have a brochure. POD Pak The POD Pak is a water purification device that is attached to the Q-POD Dispenser outlet. It is the final purification device used before Milli-Q Water is dispensed. The POD Pak provides additional quality and insurance that trace contaminants related to specific applications are removed just before ultrapure water is delivered.
Dec 29, 2017 - Save this Book to Read biochemistry acs exam study guide 2013 PDF eBook at our Online Library. Get biochemistry acs exam study guide. New editions of ACS Exams have been released as of late 2017 and early 2018: GC17PQF – 2017 First term General Chemistry Paired Questions Exam. Aug 29, 2014 - DOWNLOAD BIOCHEMISTRY ACS EXAM STUDY GUIDE 2013 biochemistry acs exam study pdf. The best way to prepare is to study one of. Biochemistry acs exam study guide. Preparing for Your ACS Examination in General Chemistry: The Official Guide. (commonly called the General Chemistry Study Guide). This guide includes 113.
2.5 Lpm Milli-Q Integral 5 4.25 Lpm Milli-Q Integral 10 8 Lpm Milli-Q Integral 15 13 Lpm RO Ionic Typical 94-99%. Dimensions Note to Millipore reviewer Drawings or photos will be used here with dimensions indicated Materials of Please contact Millipore for a list of the Materials of Construction. Construction Feedwater The Feedwater requirements are listed here. Item Description Aluminum 6 hours). This allows the purification media in the Q-Gard Pack and Quantum Cartridge to hydrate.
Replacing a POD Pak Replacement One possible reason for a decrease in Milli-Q Water flowrate is a clogged based on POD Pak. The POD Pak should be replaced when it appears to be clogged. Flowrate Make sure the POD Pak is not air-locked. Dispense water and open the vent to see if there is any trapped air. Select Menu. Press Select Maintenance. Press Scroll down until you see Install Q-POD Pak 1.
Press Press In this example, you choose Millipak. Press Press 3 times. Cleaning the A10 TOC Monitor When There is no LCD message indicating that an A10 TOC Monitor cleaning is needed. Purpose The A10 TOC Monitor cleaning is recommended when:. A new Q-Gard Pack or Quantum Cartridge is installed,. the TOC values are fluctuating, or. Press When the A10 CLEANING Mode has finished, the Milli-Q System automatically goes into READY Mode.
Sanitising or cleaning the RO Cartridge Safety Wear Eye Safety Glasses and Laboratory Gloves and other appropriate safety equipment when sanitising or cleaning the RO Cartridge(s). Opening and closing the Step Action Result Sanitisation Port Sanitising Step Action Result Cleaning Step Action Result. Purpose The purpose of the Inlet Strainer is to prevent a large particle from entering the Milli-Q System. If the Inlet Strainer becomes clogged, then feedwater does not flow freely to the Milli-Q System. Cleaning the Inlet Strainer removes any trapped debris. Replacing the Tank Vent Filter When The Tank Vent Filter should be replaced when one of the following Alert messages is displayed.
Alert message = REPLACE PROGARD AND TANK VENT FILTER. Alert message = REPLACE PROGARD AND TANK VENT FILTER OVERDUE X DAYS, where X = 1, 2,.
Alarms and Alerts Overview Purpose The purpose of this chapter is to explain the various Alarm and Alert messages shown on the Milli-Q System. Contents This chapter contains the following topics: Topic See Page Alert messages Alarm messages Summary of Alert and Alarm messages. Alert messages Purpose An Alert message corresponds to a maintenance request. Most of the Alert messages are related to the changing of a consumable. Types The following table summarizes the different types of Alert messages. Type Description.
A minor alert message corresponds to an early Minor Alert maintenance request. Some Alarms, when displayed, do not automatically Milli-Q System stop the Milli-Q System from dispensing water. An example of this is the Alarm message MILLI-Q T MAX The Feedwater Water temperature is out of measurement range. Contact Millipore. TANK EMPTY The Milli-Q System has detected an empty tank. Refill the tank. Verify that the tank level sensor is plugged into the Milli-Q System Cabinet.
ZMQSP0D01 Water Sensor ZFWATDET4 Milli-Q Integral System Cabinet Item Catalogue Number Milli-Q Integral 3 ZRXQ003T0 Milli-Q Integral 5 ZRXQ005T0 Milli-Q Integral 10 ZRXQ010T0 Milli-Q Integral 15 ZRXQ015T0 Note: A complete Milli-Q Integral System consists of:. a Q-POD Dispenser.
a Tank, and. a Milli-Q Integral System Cabinet.